Filter Results By:

Products

Applications

Manufacturers

Showing results: 1066 - 1080 of 1093 items found.

  • Dual Input True RMS AC Voltage/Current Datalogger - Datalog up to 256,000 Readings with Programmable Sample Rate from 1sec to 24hrs

    Extech DL160 - Extech Instruments Corporation

    The DL160 is a Dual Input True RMS AC Voltage/Current Data logger. Simultaneously data log 2 channels of up to 256,000 readings of TRMS AC Voltage (600V) or Current (200A) or one AC Voltage and one AC Current input with a user programmable sample rate from 1 second to 24 hours. LCD displays time/date, current reading, and min/max. Readings can be downloaded to your PC via the USB interface. Featuring Normal, Peak, and Capture (user specified trigger level) recording modes. Complete with 2 current clamps, two sets of test leads, 2 sets of alligator clips, software, USB cable, Universal AC Adapter, and 4 x AAA and 2 x CR2032 Batteries.

  • CTEK MXS 25EC Battery Charger

    56-314 - CTEK Power USA

    Designed for professional use, the MXS 25EC includes a wide range of battery charging and maintenance features, including an automatic diagnostic function that tests whether a battery is able to take and hold a charge, a RECOND function that can bring an old or marginal battery back into serviceable life and a supply function that allows it to be used as a clean power supply to support the battery and electrical system during diagnostics, reprogramming and battery and system service maintenance activities. With a built in temperature sensor, the MXS 25EC is able to compensate for special conditions and provide optimum charging whatever the weather. It has long 18 foot cables for extended vehicle / battery access and includes the CTEK Wall Hanger 300 for added in use functionality. Limited Warranty 2 Years

  • GAOTek Three-Channel Leakage Current Tester

    GT00YB00ZV - GAO Tek Inc.

    The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • 12 Channels 1.0 ~ 17.0 Gb/s (200Gbps) Pulse Pattern Generator and Error Detector

    CA9806-12 - UC Instruments, Corp.

    The UC INSTRUEMNTS CA9806-12 is a highp erformance, flexible 12 channels Pulse Pattern Generator and Error Detector that can operate from 1.0 to 17.0 Gb/s (200 G). It is combined with three sets CA9806 4 CH 1.0 to 17.0 Gbps Pulse Pattern Generator and Error Detector that incorporates an external one by 4 rate clock synthesizer. Its small size allows it to be placed close to the device under test, it can also be placed further away using the TX driver pre and post emphasis controls features to compensate for cable and interconnect losses. It also has a non destructive, integrated eye outline capture feature along with a quick eye height and width measurement capability. Build-in 8.5 ~ 15 Gb/s eye diagram testing function.

  • HD Color Bar Generator

    CBG830 - MicroImage Video Systems

    The CBG830 color bar and test signal generators will produce a quality, high definition full field color bar signal compatible with the digital HDMI and DVI-D interfaces. The CBG830 is designed to provide an accurate and affordable signal source for easy testing of displays, cables and systems.The CBG830 will generate a full field color bar signal with eight vertical bars, white through black. This signal is available in a variety of resolutions and refresh rates. TheCBG830 will usually fit in a toolbox with ease and even fit into a pocket. There is also a rack mount kit available as well. Power is provided by a regulated 5VDC source and a small wall plug power module is included with the packaged CBG830 but not with board level products. The CBG830 will have a switch array to select the video standard.

  • Automatic Calibration Module

    ACM4509 - Copper Mountain Technologies

    ACM4509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full four-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2509 - Copper Mountain Technologies

    ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Automatic Calibration Module

    ACM2520 - Copper Mountain Technologies

    ACM2520 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 20 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full 2-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to 18 connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TT Series - IBEKO Power AB

    RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • ISP Programmer Superpro Is01

    Xeltek

    Features:Until now,Support IC manufacturer, pcs devices and keeps growing.1)High speed thanks to the flexible hardware engine. Programming speed adjustable for complicated application environments brought by user target board, length of ISP cable etc.2)Stand-alone and PC-Hosted (USB2.0 High Speed) dual mode;3)Supports ISP programming of devices with I2C, SPI, UART, BDM, MON, MW, JTAG, CAN, ICC, RS232 and any other serial port.4)ATE interface;5)Over-current and ESD protection to protect your equipment;6)DLL and API for easy integration into customers’ system.Hardware Specifications:1) ISP cable integrates I2C, SPI, UART, BDM, MON, MW, JTAG, CAN, ICC, RS232 interfaces。2) VDD (0-5.5V /0.5A) and Vpp (0-15V / 0.2A) lines provided to power the target board and the target devices.3) Cable driver circuit supports target devices of voltage level 1.5-5V and is ESD protected.4) USB 2.0 (high speed) interface for PC hosted mode and management of project files on SD card.5) A 20 Characters x 4 lines LCD and a 6-key keypad are built with it for stand-alone operation. In stand-alone mode project files are stored on the SD card (up to 16GB). The number of the project files is limited only by the capacity of the SD card.6) ATE interface is built for easy external hardware control. 6 lines SEL0-SEL5 are for project selection (maximum 64 files); 2 command lines START and STOP; 3 STATUS lines PASS, FAIL and BUSY. All signals are optical-isolated.7) A universal AC adaptor of DC12V/2A is included for power supply.8)WINDOWS XP/Vista/Win7/Win8/Win10 32/64bit compatibility.Software Specifications:1) Supports almost all devices with ISP interface.2) Supports Jam and Staple files from ACTEL and ALTERA; Direct C files from ACTEL.3) Programming speed selectable (High, Normal and Low) for complicated applications such as different cable lengths, different target load characters.4) Dynamic buffer function. Application examples include device S/N, MAC address, frequency or transducer calibration etc.5) File format on SD: FAT16, FAT32.6) Functions for IP protection: Project security, SD security, batch control, administration management etc. 7) API and DLL provided for easy integration into customers’ system like ICT and ATE.8) Software provides the features for multiple units to work concurrently controlled by USB HUB.Applications:1)R&D application like in-circuit test and debug.2)Volume production. Devices may be programmed after the board is fully assembled. One example is the serial number writing to an on-board serial device.3)Field application. Comes with portability, stand-alone mode and mobile data storage media (SD card), it is suitable for field test, debug and data acquisition.4)Third application modules. Friend s/w interface (DLL and Virtual Com communication command set) and h/w interface ( ATE and USB) are provided and make it very easy for customers to integrate ISP01 as a functional module into their systems. One example is the ICT equipment. With this integration user can finish in-circuit test and in-circuit programming in one step.

  • Speaker/Receiver Unit Tester

    BK2120A - BaKo Co., Ltd

    Our new, upgraded BK2120A is a complete system for testing both acoustical features and rub & buzz in microspeakers, receivers and earphones or earbuds. It is just as fast and easy to use as our "Classic" BK2120A speaker tester, but because it connects with a LAN cable, you can use it with a notebook, as well as a PC. Its new modular design also makes maintenance more convenient and the redesigned BS1123 software is even easier to use and more versitile than the old version. You still get both graphical and numeric test data but with more display options than before. We still customize our machine to your special needs and of course you can still save your data to analyze later. Easier setup, improved design, more features, easier to use: we expect our new BK2120A to be even more popular than the original!

  • Series Flame Detector

    DF-TV7 - Teledyne Gas & Flame Detection

    The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can ​​be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs.All MultiFlame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU600 wireless hand-held unit that is approved for use in hazardous areas. The TLU600 can also be used for wireless testing of the optical and output circuits. The TLU600 can also be used for wireless testing of the optical and output circuits.​​​​​​​​​​​​​​​​​​​​

  • Multifunction Electrical Installations Meter

    MPI-525 - Sonel S.A.

    Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.

Get Help